Setting power save timers – P.SAV

17 September, 2024

Accessed via the Setup menu (see heading. below) Power Save (P.SAV) timers can be set during hours of peak power tariffs to ensure no unnecessary heating or filtration will take place during that time.

The power save setting consists of a choice of; mode, peak power period start time and peak power period end time (refer table below).

Item Description Notes
P.SAV Power Save Mode -Functions disabled during peak power periods OFF = P.SAV disabled (default)
LOW = Filtration disabled, allow heating
HIGH = Heating disabled, allow filtration
BGN Begin Time - Peak power period begins Adjustable: 00:00 - 23:59
Default = 14:00 (2PM)
END End Time - Peak power period ends Adjustable: 00:00 - 23:59
Default = 20:00 (8PM)

Important Notes

  • If P.SAV function is to be used the spa user MUST consider any sleep timers [SNZE] and adjust them accordingly. Sleep timer settings will OVERIDE any P.SAV settings
  • On older versions of software Power Save set to HIGH can = disable heating & filtering

Entering the Setup menu

The SV controllers feature an advanced setup menu which allows customisation of the adjustable controller settings.

Setup Menu

The SV controllers feature an advanced setup menu which allows customization of the adjustable controller settings. Menu item options are detailed in the list below.

  • To enter menu press and hold up-arrow and down-arrow buttons until [MODE]
    is displayed.
  • Press up-arrow  or down-arrow to navigate through menu item list
  • Press Okay to enter menu item adjustment
  • Press up-arrow or down-arrow to adjust setting
  • Press Okay to confirm setting and exit menu

Accessible options in the setup menu

Menu Item Setting Notes
MODE Operating Mode Normal / Away / Week Modes
FILT Hours of filtration per day 1 to 24 hours
F.CYC Filtration cycle blocks Set filtration to run every 1,2,3,4,6,8,12 or 24 hrs
SNZE Sleep time menu  
1.SNZ Sleep timer 1 [1.DAY] Days of week, [1.BGN] Begin Time, [1.END] End Time
2.SNZ Sleep timer 2 [2.DAY] Days of week, [2.BGN] Begin Time, [2.END] End Time
R.SET Reset sleep timers Reset sleep timers to factory defaults
EXIT Exit sleep time submenu  
P.SAV Power save settings Off, Low (off-peak filtration), High (off-peak filtration & heating)
W.CLN Automatic sanitise time Daily run time of automatic sanitise cycle (00:00 - 23:59)
D.DIS Default display mode Water Temp (W.TMP), Set Temp (S.TMP) or Clock (TIME)
T.OUT Load time out period Pump / Blower time out period (10 to 60 minutes)
H.PMP Heat pump operating mode Auto (heat or cool) / Heat / Cool / Off (heat pump disabled)
H.ELE Heat pump with SV element boost On = Heat pump + SV element combined for heating Off = Heat pump only
EXIT Exit setup menu  

Important Notes

The setup menu item settings are stored in non-volatile memory (EEPROM) and are remembered when power is turned off. No need to reprogram settings when power is restored.

A ten (10) second idle menu time out period exists. If a button press is not detected for 10 seconds, the menu will time out and the screen will return to the default display mode.

×