Setting your daily Water clean Cycle – W.CLN

17 September, 2024

SV & SV Mini controllers are automatically programmed to activate a 10-minute daily sanitisation cycle at a given time, where each pump/blower is operated to purge pipe work whilst operating the filtration pump. This setting can be adjusted via the Setup Menu (see heading below) & allows the user to choose the start time of the automatic daily sanitise cycle.

Setting ranges from 00:00 to 23:59. Default = 09:00 (9AM)

Important Notes

On SV Mini controllers W.CLN cycle is fixed to run at 9:00am. Users will not be able to adjust the start time.

All SV & SV Mini controllers will skip the auto water clean cycle if the spa has been used the day before to save on electricity consumption, as the pumps have already run & purged their pipe work.

SV2, SV3, SV4 & SmartTouch touchpads have a Water clean cycle button. When pushed the spa will run a 20min purge cycle on demand.

Entering the Setup menu

The SV controllers feature an advanced setup menu which allows customisation of the adjustable controller settings.

Setup Menu

The SV controllers feature an advanced setup menu which allows customization of the adjustable controller settings. Menu item options are detailed in the list below.

  • To enter menu press and hold up-arrow and down-arrow buttons until [MODE]
    is displayed.
  • Press up-arrow  or down-arrow to navigate through menu item list
  • Press Okay to enter menu item adjustment
  • Press up-arrow or down-arrow to adjust setting
  • Press Okay to confirm setting and exit menu

Accessible options in the setup menu

Menu Item Setting Notes
MODE Operating Mode Normal / Away / Week Modes
FILT Hours of filtration per day 1 to 24 hours
F.CYC Filtration cycle blocks Set filtration to run every 1,2,3,4,6,8,12 or 24 hrs
SNZE Sleep time menu  
1.SNZ Sleep timer 1 [1.DAY] Days of week, [1.BGN] Begin Time, [1.END] End Time
2.SNZ Sleep timer 2 [2.DAY] Days of week, [2.BGN] Begin Time, [2.END] End Time
R.SET Reset sleep timers Reset sleep timers to factory defaults
EXIT Exit sleep time submenu  
P.SAV Power save settings Off, Low (off-peak filtration), High (off-peak filtration & heating)
W.CLN Automatic sanitise time Daily run time of automatic sanitise cycle (00:00 - 23:59)
D.DIS Default display mode Water Temp (W.TMP), Set Temp (S.TMP) or Clock (TIME)
T.OUT Load time out period Pump / Blower time out period (10 to 60 minutes)
H.PMP Heat pump operating mode Auto (heat or cool) / Heat / Cool / Off (heat pump disabled)
H.ELE Heat pump with SV element boost On = Heat pump + SV element combined for heating Off = Heat pump only
EXIT Exit setup menu  

Important Notes

The setup menu item settings are stored in non-volatile memory (EEPROM) and are remembered when power is turned off. No need to reprogram settings when power is restored.

A ten (10) second idle menu time out period exists. If a button press is not detected for 10 seconds, the menu will time out and the screen will return to the default display mode.

×