SV & SV Mini controllers are automatically programmed to activate a 10-minute daily sanitisation cycle at a given time, where each pump/blower is operated to purge pipe work whilst operating the filtration pump. This setting can be adjusted via the Setup Menu (see heading below) & allows the user to choose the start time of the automatic daily sanitise cycle.
Setting ranges from 00:00 to 23:59. Default = 09:00 (9AM)
On SV Mini controllers W.CLN cycle is fixed to run at 9:00am. Users will not be able to adjust the start time.
All SV & SV Mini controllers will skip the auto water clean cycle if the spa has been used the day before to save on electricity consumption, as the pumps have already run & purged their pipe work.
SV2, SV3, SV4 & SmartTouch touchpads have a Water clean cycle button. When pushed the spa will run a 20min purge cycle on demand.
The SV controllers feature an advanced setup menu which allows customisation of the adjustable controller settings.
The SV controllers feature an advanced setup menu which allows customization of the adjustable controller settings. Menu item options are detailed in the list below.
The setup menu item settings are stored in non-volatile memory (EEPROM) and are remembered when power is turned off. No need to reprogram settings when power is restored.
A ten (10) second idle menu time out period exists. If a button press is not detected for 10 seconds, the menu will time out and the screen will return to the default display mode.
Show all